If you wish to contribute or participate in the discussions about articles you are invited to contact the Editor
File talk:Galileo Signals in Space.png
Jump to navigation
Jump to search
[JAAR 7] The figure is incorrect! PRS is not in phase with any of the OS services (neither data nor pilot) or CS. In fact, Galileo OS and CS data and pilot are in phase and PRS is in quadrature to both. In addition, in E1 although you write MBOC, in reality it is the spectrum of BOC(1,1). Moreover, avoid writing the value of power of the PRS as this is not indicated in open ICDs. In other words, neither E1 nor E6 reflect the correct phasing between PRS and the rest of services